Products | Dust-collector, Scrubber | MCB multi-cycloneApplicationThe multicyclone stations are applied in a wide variety in metal and carbon mines, cement and other building industry technologies, cleaning of smoke-gas in coal-dust firing furnaces, in metallurgy, also used in chemical industry, food industry and agriculture. It is recommended that the cyclones are not used or used with special care for flammable dust, liability to static charge, abrasive and high-temperature explosive gases.
Notation, typesThe multicyclone stations are available in stations with 1,2,4,6,8 pieces made from standards.
Special types: B,N,H, K The number of parts in a multicyclone station can be: 1,2,4,6,8,12,16.
Technical data
Flowrate:
The Vn nominal flowrate is approx.: 16 m/s is equal to optimal instep speed. The volume limits are: Vmin=0,75 Vn Vmax=1,25 Vn in average case.
Pressure loss(resistance) The optimal: with instep speed of 16 m/s the MCB-2 cyclone station's resistance is approx.: pt = 850 Pa, the MCB-4 cyclon station's resistance is approx.: pt = 1100 Pa. Dusting level: According to measurements from laboratories, the total dusting level is approximately 97% for the MCB-4 cyclone station, according to the research that was made with air temperature of 20°C, with 10g/m3 input dustconcentration, with DIN100 silica flour testpowder. Energy requirement: The specific energy requirement with the 16m/s optimal entering speed is: for MCB-2 version: Pf = 0,23 kW/1000 m³/h for MCB-4 version: Pf = 0,30 kW/1000 m³/h |